
Call us now
08045800648
Physical | 1RU Fixed Form Factor
Cisco Nexus 3064-X: 64 10 Gigabit Ethernet ports (48 SFP+ and 4 QSFP+) 48 SFP ports support 1 and 10 Gigabit Ethernet 4 QSFP ports support 4 x 10 Gigabit Ethernet or 40 Gigabit Ethernet each 2 redundant power supplies 1fan tray with redundant fans 1 I/O module with management, console, and USB flash memory ports |
|
Performance | 1.28-Tbps Switching Capacity
Forwarding rate of 950 mpps Line-rate traffic throughput (both Layer 2 and 3) on all ports Configurable maximum transmission units (MTUs) of up to 9216 bytes (jumbo frames) |
|
Hardware Tables And Scalability | MAC Addresses | 128,000 |
Number Of VLANS | 4096 | |
Spanning-Tree Instances | Rapid Spanning Tree Protocol (RSTP): 512
Multiple Spanning Tree (MST) Protocol: 64 |
|
ACL Entries | 2000 Ingress
1000 egress |
|
Routing Table | 16,000 Prefixes And 16,000 Host Entries
8000 multicast routes |
|
Number Of EtherChannels | 64 (With PC) | |
Number Of Ports Per EtherChannel | 32 | |
Buffers | 9 MB Shared | |
Boot Flash Memory | 2 GB | |
Power | Number Of Power Supplies | 2
Cisco Nexus 3064-X: Redundant for AC and DC power |
Power Supply Types | AC (Forward And Reversed Airflow)
DC (forward and reversed airflow) |
|
Typical Operating Power | Cisco Nexus 3064-X
143 watts (W; 64p with Twinax at 100% load; 2 power supply units [PSUs]) 177W (64p with SR optics at 100% load; 2 PSUs) |
|
Maximum Power | Cisco Nexus 3064-X: 199W | |
AC PSUs
Input voltage Frequency Efficiency |
100 to 240 VAC 50 to 60 Hz 89 to 91% at 220V |
|
DC PSUs
Input voltage Maximum current Efficiency |
-40 to -72 VDC 33A 85 to 88% |
|
Typical Heat Dissipation | Cisco Nexus 3064-X
488 BTU/hr (64p with Twinax at 100% load; 2 PSUs) 605 BTU/hr (64p with SR optics at 100% load; 2 PSUs) |
|
Maximum Heat Dissipation | Cisco Nexus 3064-X: 683 BTU/Hr | |
Cooling | Forward And Reversed Airflow Schemes:
Forward airflow: Port-side exhaust (air enters through fan-tray and power supplies and exits through ports) Reversed airflow: Port-side intake (air enters through ports and exits through fan-tray and power supplies) Single fan tray with redundant fans Hot swappable (must swap within 1 min) |
|
Sound | Measured Sound Power (Maximum)
Fan speed: 40% duty cycle Fan speed: 60% duty cycle Fan speed: 100% duty cycle |
59.7 dBA 66.4 dBA 71.0 dBA |
Environment | Dimensions (Height X Width X Depth) | Cisco Nexus 3064-X: 1.72 X 17.3 X 19.7 In. (4.4 X 43.9 X 50.5 Cm) |
Weight | Cisco Nexus 3064-X: 20.5 Lb (9.3 Kg) | |
Operating Temperature | 32 To 104F (0 To 40C) | |
Storage Temperature | -40 To 158F (-40 To 70C) | |
Operating Relative Humidity | 10 To 85% Noncondensing
Up to 5 days at maximum (85%) humidity Recommend ASHRAE data center environment |
|
Storage Relative Humidity | 5 To 95% Noncondensing | |
Altitude | 0 To 10,000 Ft (0 To 3000m) |
Price: